Ultrasonic Detector (UD)

|
-
- Install ultrasonic detector right above every parking space to collect the real-time parking space information through the principle of ultrasonic, measuring the distance and transmit its feedback to led indicator and node controllers through RS-485.
|
Voltage rating: |
DC24V |
Current rating: |
30MA |
operational principle: |
Ultrasonic |
communication port: |
RS 485 |
detection range: |
0.5-3.5M |
detection range setting: |
Range tolerance 0.5m |
Max error: |
0.05M |
detection angle: |
15° |
response time: |
30ms |
Size: |
10㎝ (diameter)×2.3㎝(height) |
Shell material: |
ABS |
|
LED Indicator

|
Install LED Indicator in the front of every parking space to display the current parking space status. When the indicator displays green, it means the parking space is available, when the indicator displays red, it signifies it is occupied.
|
Voltage rating: |
DC5V |
Current rating: |
35mA |
LED luminance (Green/Blue): |
9000mcd |
LED luminance(RED): |
5000mcd |
LED number: |
4 RED 4 Green/Blue |
Shell: |
ABS |
working temperature: |
-50℃~ +80℃° |
visual angle: |
360° |
visual range: |
>50m |
|
Zone Control Unit(ZCU)
.jpg)
|
The zone control unit(ZCU) is the middle layer of ultrasonic parking detector, which be used to manage grouply ultrasonic detector, detect loop the information of the detector, then send the relevant information to central controller. One node controller can control 40-60 parking space detectors.
|
Voltage rating: |
DC24V |
Current rating: |
45mA |
Output port: |
RS 485(1,2,3) |
Communication frequency: |
9600 |
Rs485(1): |
To CCU |
Rs485(2): |
To UD(sensor) |
Control quantity: |
60 sub-node(UD/screen) in max |
|
Central Control Unit (CCU)

|
Central controller(CCU), the core of the whole system, is mainly responsible for the collection of carport information and data processing of the whole yard. Then send the feedback of the processing result to LED display to show carport information. |
Voltage rating: |
DC5V |
Current rating: |
100mA |
Output port: |
com1, com2/com3 |
Communication frequency: |
9600 |
com2: |
To PC |
com1: |
To ZCU |
Control quantity: |
60 sub-node(ZCU/screen) |
|
LED Indoor Screen

|
Receive the carport information from central controller(CCU) and display the amount of the available lots currently in terms of number and word and can be used 24hours a day. Internal procedure can be revised at any time according to the demands of the users,displaying other needed information. |
Voltage rating: |
DC5V |
Current rating: |
5A |
Communication port: |
RS485 |
Communication frequency: |
9600 |
Luminance: |
>500cd/m2 |
Panel size: |
36cm*12cm/48cm*18cm |
Panel display: |
48*16 / 64*24 |
|
LED Outdoor Screen

|
Outdoor LED display is comprised by high intensity outdoor LED module, driving circuit, controlling circuit,frame and other parts. It receives the statistic information of the parking space from the central controller, displaying the amount of available parking spaces in real time and can be used 24 hours a day. Internal procedure can be revised at any time according to the users’ demands, displaying other information. |
Voltage rating: |
DC5V |
Current rating: |
5A/20A |
Communication port: |
RS485 |
Communication frequency: |
9600 |
Luminance: |
1000cd/m2 |
Panel size: |
32CM*16CM/64cm*32cm |
Panel display: |